Test Point 44
TEST POINT 44
Servo motor, Central Locking System Short To B+
Fault Code 45
Fault Effect: No central locking or unlocking possible
Procedure
1. Pull plug II off the alarm system control module.
2. Disconnect plug connection X 11 (driver's side).
3. Disconnect plug connection X 12 (passenger's side).
4. Switch ignition on.
5. Connect voltmeter to plug II, pin 9 and ground.
Display: 0 volts
6. Connect voltmeter to plug II, pin 3 and ground.
Display: 0 volts
7. Switch off ignition.
8. Ohmmeter at plug X 11, pin S-11 and pin S-24 (sleeve side).
Display: 5 - 7 ohms @ 20 °C
9. Ohmmeter at plug X 11 pin S-11 and pin S-17 (sleeve side).
Display: 5 - 7 ohms @ 20 °C
10. Ohmmeter at plug connection X 12, pin 11 and pin 24 (sleeve side).
Display: 5 - 7 ohms @ 20 °C
11. Ohmmeter at plug connection X 12, pin 11 and pin 24 (sleeve side).
Display: 5 - 7 ohms @ 20 °C