Fault Code 2
FAULT CODE 2
motor Circuit, Right
This fault is stored in the following cases:
1. Short circuit to ground or open circuit in the circuit between control module and servomotor for HBA, right, terminals 5, 6, 7, 8
2. Servomotor for HBA, right, is faulty
3. The control module is faulty
Fault Effect: No automatic adjustment possible
Elimination:
- Switch off ignition
- Pull plug off the control module
- Pull plug off the servomotor for HEA
- Check for open circuit in the supply leads to the servomotor for HBA, right, terminals 5, 6, 7, 8
Ohmmeter display: < 5 ohms
- Check for short to B+ in the supply leads to the servomotor for HBA
- Ohmmeter connected to terminals 5, 6, 7, and 8; measure resistance ro ground
Display: infinity
- Check for short circuits between the leads.
- If no fault is detected in the wires, replace the servomotor for HBA.