Test Point 1
TEST POINT 1
Interface To The Instrument Cluster Open Circuit, Short To Ground
DTC 20
Fault Effect: Substitute values *
Diagnosis Conditions
- No control module fault stored.
- No fault on the supply voltage (terminal 15).
Open Circuit
1. Pull off connector B on the heating/air conditioning control.
2. Pull off connector III on the instrument cluster.
3. Connect ohmmeter to connector B 13 and to connector III, pin 26.
Display: < 5 ohms
Note:
The wire is routed via the 12-pole plug connection on the heater/ A/C unit.
Short To Ground
1. Pull off connector B on the heating/air conditioning control.
2. Pull off connector Ill on the instrument cluster.
3. Connect ohmmeter to connector B 13 and ground.
Display: infinity
If 0 - 5 ohms is displayed, check the wiring for pinching and chafing.
* Outside temperature: 10 °C
Engine temperature: 80 °C
Vehicle speed: 70 km/h
Engine speed: 1000 rpm