P1110
P1110
294 Oxygen Sensors Exchanged Ahead of TWC
Diagnosis conditions
- Engine at operating temperature
- Oxygen sensing system active
Possible fault cause
- Wiring harness
Affected terminals
II/15 and II/16
Diagnosis/Troubleshooting
NOTE: When the oxygen sensors are exchanged, then the oxygen sensors run contrary to the adaptation limitation.