Ambient Temperature Sensor / Switch HVAC: Service and Repair
Removing and installing outside temperature sensor
Removing and installing outside temperature sensor on the installed heating/air-conditioning unit
Removal
1. Remove footwell bulkhead and right-hand air guide. Remove drive motor for fresh-air/recirculation valve.
2. Pull off electrical plug connection on the outside temperature sensor. Turn temperature sensor by 90 ° and pull it out.
Installation
1. Place temperature sensor on the intake duct and turn by 90 ° (tighten).
2. Engage electrical plug connection and route the wire carefully.
3. Install drive motor for fresh-air/recirculation valve and perform a function test.