CD Changer (CDC)
CD Changer (CDC)
The CDC is available as an optional feature and is linked to the PCM2 via the optical waveguide.
NOTE:
- When trying to remove the electrical plug connection it may be that, because tolerances are too tight, this cannot be done. In this case remove the holder on the CD changer. Remove the side cover above the electrical plug connection and lift off. Using the appropriate tool between the plug and the housing, carefully make a gap of about one millimeter so that the latch can be disengaged from the cover and the plug can be pulled off.
- On the PCB under the cover there is a glass fuse (3 amps); if the CD changer voltage supply fails, check this and replace if necessary.