Operation CHARM: Car repair manuals for everyone.

P0040



P0040

Oxygen Sensors In Front Of Catalytic Converter Exchanged - Signal Implausible

Diagnostic conditions
- Battery positive voltage between 10 V and 16 V
- Oxygen sensing system active

Possible cause of fault
- Oxygen sensors ahead of catalytic converter exchanged
- Line polarity reversal

Affected pins
DME control module, connector A, pin 4, and oxygen sensor ahead of catalytic converter, bank 2, pin 4
DME control module, connector A, pin 5, and oxygen sensor ahead of catalytic converter, bank 1, pin 4
DME control module, connector A, pin 12, and oxygen sensor ahead of catalytic converter, bank 2, pin 5
DME control module connector A, pin 13, and oxygen sensor ahead of catalytic converter, bank 2, pin 1
DME control module, connector A, pin 14, and oxygen sensor ahead of catalytic converter, bank 2, pin 2
DME control module, connector A, pin 15, and oxygen sensor ahead of catalytic converter, bank 2, pin 6
DME control module, connector A, pin 51, and oxygen sensor ahead of catalytic converter, bank 1, pin 5
DME control module connector A, pin 52, and oxygen sensor ahead of catalytic converter, bank 1, pin 6
DME control module, connector A, pin 70, and oxygen sensor ahead of catalytic converter, bank 1, pin 1
DME control module, connector A, pin 71, and oxygen sensor ahead of catalytic converter, bank 1, pin 2

Diagnosis/troubleshooting

NOTE: The oxygen sensors ahead of the catalytic converter can only be exchanged in naturally aspirated V8 engines. If this fault is recorded for a turbo V8 engine, however, it can only be caused by polarity reversal in the wiring harness (e.g. following accident repairs).

WARNING: Always observe the notes on possible dangers, the warning and caution notes as well as the general instructions in the introduction.

NOTE:
- Do not use contact spray on the oxygen sensor plug connections, as this may cause irreparable damage to the wiring (blocking the reference air channels).
- Do not confuse oxygen sensor ahead of catalytic converter and oxygen sensor behind catalytic converter as this will cause implausible fault entries.

Distinguishing feature of both sensors:







Oxygen sensor in front of catalytic converter (LSU) has a six-pin connector







Oxygen sensor behind catalytic converter (LSF) has a four-pin connector

NOTE: The diagnosis detects contrary adaptation values for oxygen sensor. If the adaptation values reach the control limits in opposite directions, interchanged oxygen sensors will be detected.


Part 1:




Part 2: