P0282
P0282
Injection Valve On Cylinder 8 - Open Circuit
Diagnostic conditions
- Engine running
- Battery positive voltage greater than 8 V
Possible cause of fault
- Short circuit to ground in control line of injection valve
- DME control module faulty
Affected terminals
DME control module plug A, pin 19, and pin 2 of injection valve
Diagnosis/troubleshooting
NOTE: Connection KE 7 is located on the bottom of the radiator tank E-box.