P1610
P1610
CAN Time-out, Climate Control
Diagnosis conditions
- Battery positive voltage between 10 V and 16 V
- Ignition switched on
- Internal function test for DME control module
Possible fault cause
- No communication possible with air-conditioning control module (no signal from air-conditioning control module)
Affected pin
DME control module connector A, pin 60, CAN - HIGH
DME control module connector A, pin 58, CAN - LOW
Diagnosis/troubleshooting
NOTE:
- If the received signal does not appear via the CAN data bus for multiple control modules, the CAN data bus must be checked for an open circuit and/or a short circuit. In this regard, see Checking instructions/CAN data bus.
- If connector A is disconnected from the DME control module and the ignition is or was switched on, the DME Control Module TIME-OUT fault is recorded in many control modules.
- If control module connector A was disconnected from the DME in the course of troubleshooting or if the voltage supply was interrupted elsewhere (battery, fuse), the throttle adjusting unit must be adapted.