Technical Data, Air-Conditioning System
Technical data for air-conditioning system
General pressures bar
High-pressure cut-off 32
Low-pressure cut-off at ambient temperature > 5°C 1.4 (1.0)
High-pressure cut-off at ambient temperature < 5°C 0,5
Pressure relief valve purge pressure 40