P2270
P2270Diagnosis information - DME V8 DFI
Oxygen sensor downstream, bank 1 - signal too lean / rich
NOTE:
This fault is detected if the oxygen sensor signal upstream deviates by a certain value from the control value (rich/lean mixture) within a certain time.
Diagnosis is initiated by fault detection in the mixture control.
Diagnostic conditions
- II Relatively long drive in various operating states
- Diagnoses >Electrical fault of oxygen sensor downstream [or] Lambda correction downstream< must have taken place
Possible fault causes
- Leak in exhaust system between the two oxygen sensors on bank 1
- Oxygen sensor downstream, bank 1, faulty