Ambient Temperature Sensor / Switch HVAC: Service and Repair
WM 872219 Removing and installing air-quality sensor
Preliminary work
Partially detach the cowl panel cover. Loosen fastening screws and lift the cover. -> 664419 Removing and installing cowl panel cover - section on "removing" Service and Repair
Removing air-quality sensor
Information
- The air quality sensor is located in the direction of travel tucked under the cowl panel cover on the left side.
1. Lift cover -arrow A- , release the sensor -arrow B- and pull down from the mount - cowl panel cover -arrow C-.
Removing air quality sensor
2. Release plug -a- and remove from sensor.
Pulling off plug
3. Remove air quality sensor.
Installing air-quality sensor
1. Push plug onto air quality sensor until it is felt to engage.
Plugging in connector
2. Push sensor onto mount - cowl panel cover - until the sensor clicks into place. Check it is secure.
Installing air quality sensor
Subsequent work
Position cowl panel cover and screw down with the fastening screws. -> 664419 Removing and installing cowl panel cover - section on "installing" Service and Repair