P0931
P0931
Diagnosis Information - PDK
Actuator solenoid R/P interlock, short circuit to ground
Diagnostic conditions
The control unit initially tests internal function sequences when the ignition is switched on (terminal 15). If they are OK, all diagnosable outputs are then tested and any faults are stored.
- The following fault is not saved: P1833
- The following fault is not saved: P183B
Possible fault causes
- Line between selector lever control unit and PDK control unit faulty
- Actuator solenoid for R/P interlock faulty
- PDK control unit faulty
Fault effects
- Transmission limp-home indication in instrument cluster control unit