P1346
P1346
Diagnosis Information - DME (DFI)
Valve lift control, both banks
NOTE:
- Diagnosis detects that the valves of both banks are stuck in the small or large lift by way of the vibration behavior of the camshafts.
Diagnostic conditions
- Produce small lift:
- Time after engine starts > 5 minutes
- Engine speed between 1,250 rpm and 1,600 rpm
- Mass air flow between 180 mg/stk and 350 mg/stk
- Produce large lift:
- Time after engine starts > 5 minutes
- Engine speed between 1,250 rpm and 2,100 rpm
- Mass air flow between 300 mg/stk and 600 mg/stk
Possible fault causes
- Engine oil pressure too high or too low
- Both solenoid hydraulic valves faulty