P183B
P183B
Diagnosis Information - PDK
Power supply for P/R actuator solenoid, short-circuit to B+
Diagnostic conditions
The control unit initially tests internal function sequences when the ignition is switched on (terminal 15). If they are OK, all diagnosable outputs are then tested and any faults are stored.
- Ignition on
- The following fault is not detected: P1752
Possible fault causes
- Line between selector lever control unit and PDK control unit faulty
- Selector lever control unit faulty
- PDK control unit faulty
Fault setting conditions
- Actual measured voltage HS4 > 4 V
Fault effects
- Shiftlock power supply switch-off
- Shiftlock function switch-off
- No shift-lock function
- Selector lever is blocked in P and can be released only mechanically (emergency release)