U0073 DME control module, communication
U0073
DME control module, communication
NOTE: Internal function test completed.
Diagnostic conditions
The DME control module initially tests internal function sequences after wake-up. If they are OK, all diagnosable outputs are then tested and any faults are stored.
DME control module wake-up through:
- event-induced CAN message
- "Ignition on"
Possible fault causes
- No power supply for DME control module
- DME control module incorrectly coded
- Short circuit or open circuit in the CAN drive
- DME control module faulty (in most cases the cause is not the DME control module but incorrect coding.)
Fault effects
- Communication via the CAN drive is no longer possible.
- No other control modules are able to communicate with the DME control module.
Affected contacts on the DME control module connector
Connector A:
- 1 power supply - terminal 30
- 2 power supply - terminal 15
- 4 ground supply - terminal 31
- 5 ground supply - terminal 31
- 6 ground supply - terminal 31
Connector D:
- 36 CAN drive high
- 37 CAN drive low