P0136
P0136Diagnosis information - DME (DFI)
Oxygen sensor behind cat. conv., bank 1
NOTE: The switching times (rich/lean) of the oxygen sensor (dynamic response) are tested during and after the overrun phases.
Diagnostic conditions
- Engine running
- At operating temperature
- Overrun phase
Possible fault causes
- Misfires on this or the opposite bank
- Oxygen sensor faulty