P1696

P1696

Diagnosis information - DME (DFI)

Generator, electrical fault

NOTE: The actual voltage supplied by the generator deviates from the required setpoint voltage (13.5 ... 15.5 V).

Diagnostic conditions
- Engine running

Possible fault causes
- Drive belt incorrectly adjusted /faulty
- Generator faulty