P1697
P1697Diagnosis information - DME (DFI)
Generator, mechanical fault
NOTE: The generator is not turning or hardly turning.
Diagnostic conditions
- Engine running
Possible fault causes
- V-belt heavily slipping (e.g. due to wetness)
- V-belt loose or faulty (torn)
- Foreign body in generator