Operation CHARM: Car repair manuals for everyone.

P0050

P0050

Diagnosis information - DME V6 DFI

Driver for oxygen sensor heater ahead of catalytic converter, bank 2

NOTE: Do not use contact spray on the oxygen sensor's plug connections as this will result in irreparable damage to the lines (blockage of reference air duct).

NOTE: Do not interchange the oxygen sensor ahead of catalytic converter with the sensor behind the catalytic converter as this will result in implausible fault entries.

Diagnostic conditions
- Battery positive voltage between 9 V and 16 V
- Time after engine starts > 10 seconds
- Oxygen sensor heater ahead of catalytic converter active

Possible fault causes
- Short circuit to B+
- Short circuit to ground
- Open circuit in line
- Fuse FE 17 faulty (fuse carrier in plenum panel E-box)
- Loose contact in connector
- Oxygen sensor heater faulty
- Oxygen sensor faulty

Affected contacts on the DFI control unit connector
Connector [B]:
- Contact 73

Affected contacts on the oxygen sensor connector behind catalytic converter, bank 2
- Contact 3