P0160
P0160Diagnosis information - DME V6 DFI
Oxygen sensor behind cat. conv., bank 2
NOTE: Do not use contact spray on the oxygen sensor's plug connections as this will result in irreparable damage to the lines (blockage of reference air duct).
NOTE: Do not interchange the oxygen sensor ahead of catalytic converter with the sensor behind the catalytic converter as this will result in implausible fault entries.
Diagnostic conditions
- Exhaust temperature between 350 °C (662 °F) and 800 °C (1,472 °F)
- Battery positive voltage between 11 V and 16 V
- 200 seconds after engine start
Possible fault causes
- Open circuit in signal line and / or ground line of oxygen sensor
- Loose contact in connector
- Open circuit in positive and / or negative line of oxygen sensor heater
- Oxygen sensor faulty (heating resistor or cable)
Affected contacts on the DFI control unit connector
Connector [B]:
- Contact 54
- Contact 55
Affected contacts on the oxygen sensor connector behind catalytic converter, bank 1
Connector [A]:
- Contact 3
- Contact 4