P0274
P0274Diagnosis information - DME V6 DFI
Injection valve for cylinder 5
Diagnostic conditions
- Battery positive voltage > 8 V
- Engine running
Possible fault causes
- Open circuit in activation line
- Short circuit to ground in control line
- Short circuit to B+ in activation line
- Injection valve faulty
Affected contacts on the DFI control unit connector
Connector [A]:
- Contact 32
Affected contacts on the injection valve connector
- Contact 1