P0643
P0643Diagnosis information - DME V6 DFI
Sensor voltage 1
NOTE:
A fault is detected when:
- voltage drops below 4.7 V (P0642)
or
- voltage exceeds 5.3 V (P0643)
Diagnostic conditions
- Engine running > 5 seconds
Possible fault causes
- Short circuit to B+ or ground in the lines or connected components
Affected contacts on the DFI control unit connector
Connector [A]:
- Contact 37
- Contact 26
Connector [B]
- Contact 58