P0651
P0651Diagnosis information - DME V6 DFI
Sensor voltage 2
NOTE:
A fault is detected when:
- voltage drops below 4.7 V (P0652)
or
- voltage exceeds 5.3 V (P0653)
Diagnostic conditions
- Engine running > 5 seconds
Possible fault causes
- Short circuit to B+ or ground in the lines or connected components
Affected contacts on the DFI control unit connector
Connector [A]:
- Contact 37
- Contact 26
Connector [B]
- Contact 58