P1606
P1606Diagnosis information - CAN
Fault entry in specified control unit
NOTE: Internal function test completed.
Diagnostic conditions
The control unit initially tests internal function sequences after wake-up. If they are OK, all diagnosable outputs are then tested and any faults are stored.
Control unit wake-up through:
- Event-induced CAN message
- Wake-up signal via wake-up line
- key contact (terminal S)
- Ignition on
Possible fault causes
- Control unit is incorrectly coded
- Periphery connected to specified control unit is incorrect
- Control unit faulty (in most cases the cause is not the control unit but incorrect coding.)
Fault effects
- The specified control unit sends only substitute values via the CAN.
- Other control units detect these substitute values and set this fault code.