P2089

P2089

Diagnosis information - DME V6 DFI

Driver for intake camshaft adjustment

NOTE:
If the fault P2088 is detected, the camshaft goes to its maximum adjusting angle.
If the fault P2089 is detected, the camshaft remains at its initial position or returns to this (no adjustment).

Diagnostic conditions
- Battery positive voltage 9 ... 16 V
- Time after engine starts > 10 seconds

Possible fault causes
- Open circuit in activation line
- Short circuit to ground in activation line
- Short circuit to B+ in activation line
- Open circuit in voltage supply
- Fuse F12 faulty (fuse carrier in plenum panel E-box)
- K7 connection point disconnected
- Intake camshaft adjuster faulty
- Solenoid hydraulic valve faulty

Affected contacts on the DFI control unit connector
Connector [A]
- Contact 20

Affected contacts on the intake camshaft adjuster connector
- Contact 1
- Contact 2

NOTE: The line for fuse F12 and contact 1 of the intake camshaft adjuster connector is routed via contact 4 of the KE 7 connection point.