P2414
P2414Diagnosis information - DME V8 DFI
Oxygen sensor ahead of catalytic converter bank X - in air
NOTE: Do not use contact spray on the oxygen sensor's plug connections as this will result in irreparable damage to the lines (blockage of reference air duct).
NOTE: Do not interchange the oxygen sensor ahead of catalytic converter with the sensor behind the catalytic converter as this will result in implausible fault entries.
Diagnostic conditions
- Engine running
- Lambda control active
- Vehicle not in overrun phase
Possible fault causes
- Specified oxygen sensor not installed in exhaust flow