600613 Mounting Roof Assembly On Assembly Fixture
WM 600613 Mounting roof assembly on assembly fixture
Tools
Technical values
Mounting roof assembly on assembly fixture
CAUTION
Risk of damage to roof assembly when removed.
- Placing the roof assembly on a level surface can damage the roof assembly frame.
-> Only work on the removed roof assembly when the roof assembly is mounted on the assembly fixture. -> 6006IN Mounting roof assembly on assembly fixture
Overview of mounting roof assembly on assembly fixture
1. Get the assembly fixture ready.
1.1. Retaining frame 9695 -2- must first be fitted into the => WE1082 transmission jack V.A.G 1383 A -1-.
Securing support on retaining frame
1.2. Support 9695/1 -3- must be secured to the retaining frame 9695 -2- at the positions shown using fastening screws and inlay nuts.
1.3. Support 9695/1 -3- must then be aligned to the => dimension A: 80 mm and the => dimension B: 975 mm.
Aligning support to retaining frame
2. Secure roof assembly to the assembly fixture.
2.1. Position roof assembly -4- on the support 9695/1 -3- and secure with fastening screws (M8 x 30).
Securing roof assembly to the assembly fixture