Roll Bar: Testing and Inspection
WM 697201 Checking roll-over protection system
Tools
Preliminary work
1. Fully open the convertible top.
General warning notes
Safety instructions for work on the roll-over protection system
WARNING
Incorrect handling of roll-over protection system
- Roll-over protection system is activated
-> Remove ignition key.
-> Wait 1 minute before starting work.
-> Keep space clear for the roll-over protection system to move.
-> Only remove roll-over bar module when the roll-over bar is extended.
It is not permissible to perform repairs on the roll-over bar modules.
The roll-over bar modules must be replaced in the event of visible damage or pressure marks.
After assembly work on the roll-over protection system - but at least every 2 years - the function of the roll-over protection system must be tested by triggering it via the diagnostic interface of the PIWIS tester 9718.
Only perform the function test on the roll-over protection system with the hardtop and cap removed and the convertible top open.
Checking roll-over bar
Information
Actuate the roll-over protection system only if:
- the hardtop is removed
- the convertible top is open
- the caps are removed
1. PIWIS Tester 9718 must be connected to the diagnostic socket. Switch on ignition. Select menu item "Airbarg/POSIP" , and select menu item "Drive links" in the command line which then appears, select "Triggering roll-over bar" in the command line that appears. Press the key combination [F2] and [F8] within 2 s, as described in the Tester; the roll-over protection system is triggered. Please note: time until triggered approx. 10s!
Triggering roll-over protection system
2. Press locking levers outward -arrow A- and press in the roll-over bar -1- ( -arrow B- ) until it is felt to engage -inset-.
Pressing in the roll-over bar
Subsequent work
1. Install caps.
2. Close convertible top.