Ambient Temperature Sensor / Switch HVAC: Service and Repair
WM 872219 Removing and installing air quality sensor
Technical values
Preliminary work
Remove right cover in the cowl panel cover. -> 664419 Removing and installing cowl panel cover - section on "Removing" Service and Repair
Removing air quality sensor
NOTICE
Voltage peaks
- Risk of damage to load or to the control unit
-> Remove the ignition key and switch off load before disconnecting or removing load.
Installation position of air quality sensor
1. Unscrew inner fastening screw -1- on DME control unit bracket and remove water drip pan -2-.
Removing DME control unit bracket
2. Turn air quality sensor -1- ( -B- ) and move to the rear to remove it.
Removing air quality sensor
3. Release electric plug connection in order to release the locking mechanism using a screwdriver -a- and slide circlip -1- in direction of arrow -b- , then pull off the connector -A-.
Disconnecting connector from air quality sensor
Installing air quality sensor
1. The air quality sensor is installed in reverse order to removal.
2. Insert water drip pan -2- and tighten fastening screw -1- to => Tightening torque: 8 Nm (6 ftlb.).
Installing water drip pan
Subsequent work
Install right cover in the cowl panel cover. -> 664419 Removing and installing cowl panel cover - section on "Installing" Service and Repair