P1024
P1024Diagnostic information - DME (DFI)
Fuel high-pressure too high after engine off
NOTE: After the engine is shut off, the diagnostics detects if the fuel high-pressure does not decrease or decreases too slowly.
Diagnostic conditions
- Battery positive voltage more than 9 V
- Engine start detected more than 5 sec.
- Engine temperature -10 °C ... +100°C (14 °F ... 212 °F)
- Shut engine off and wait 10 sec.
Possible fault causes
- Loose contact or corrosion on connectors or lines green arrow Fuel high-pressure sensor
- Quantity control valve in the fuel high-pressure pump faulty