P052C
P052CDiagnosis information - Control unit DME (DFI)
Adjustment Intake camshaft Bank 2 to Cold starting
- during Catalytic converter heating measure
Information:
- If only the fault for camshaft position timing after cold start is entered, particular attention should be paid to causes such as viscous engine oil or components that stick when cold.
- The catalytic converter heating measures take place for a limited time under certain conditions (cold start).
- These include dual injection, ignition retard, additional camshaft adjustment, ...
Diagnostic conditions
- Cold starting with Catalytic converter heating measure
- then Engine speed 1200 ... 6000 rpm
- none of the following faults stored : P0010, P0020, P2088, P2089, P2092, P2093
Possible fault causes
- Engine oil pressure too low
--> ( e.g. Oil thickening, Oil quality incorrect incorrect,, Oil pressure control or Oil pump stiff / stuck ))
- Solenoid valve, hydraulic camshaft adjustment stiff / stuck
- Camshaft adjustment stiff / stuck
- Intake camshaft stiff / stuck
Fault setting condition(s)
- Deviation Actual value - Nominal value Intake camshaft too high
or