Operation CHARM: Car repair manuals for everyone.

P0692

P069200

Diagnosis information DME control unit

Radiator fans Activation

Diagnostic conditions
The control unit must be active in order to test internal function sequences and diagnosable inputs/outputs.
In the event of a fault, check whether the fault is permanently >present<. To perform the check, erase the fault memory, meet the diagnostic conditions and read out the fault memory again.
- Ignition on

Possible fault causes
- Short circuit to B+/ground/between lines or open circuit in the lines

Fault setting condition(s)
- PWM signal to Radiator fan control module Short circuit Voltage Battery
- PWM signal to Radiator fan control module Open circuit

NOTE:
Diagnosis/Fault finding.
- Check of electrical wiring and connectors
- Current measurement shows a square-wave signal in OK case
- Voltage measurement of control line displays approximately the battery voltage
- Supply voltage U ~ 12 V