Mechanical Fault / Over Temperature
P261C00Diagnosis information DME control unit
Auxiliary coolant pump
DANGER
High voltage.
Death or severe injuries due to high voltage or high current.
- De-energise the vehicle in accordance with the guidelines.
- Work must not be performed on parts carrying a high voltage.
Diagnostic conditions
The control unit must be active in order to test internal function sequences and diagnosable inputs/outputs.
In the event of a fault, check whether the fault is permanently >present<. To perform the check, erase the fault memory, meet the diagnostic conditions and read out the fault memory again.
- Ignition on
Possible fault causes
- Mechanical fault
- Overtemperature
NOTE:
Diagnosis/Fault finding.
- Check electric water pump for Sluggishness
- Check electric water pump for Overtemperature (> 160 °C / 320 °F)