Starter Motor
No Load and Load Tests<saacc44002-004>
No Load Condition | Minimum Cranking Voltage | 11.5 Volts (V) |
Amperage | 35-55 at 6500-8500 _Amperes At RPM (A @ rpm) | |
Loaded Condition | Minimum Cranking Voltage | 9 Volts (V) |
Amperage | 205-235 at 1000-1300 _Amperes At RPM (A @ rpm) | |
Locked Stator Condition | Minimum Cranking Voltage | 6 Volts (V) |
Amperage | 450-555 at 0 _Amperes At RPM (A @ rpm) |