Distribution Terminal +X
Distribution Terminal +X:
Operation
The positive supply is taken from battery 1 to ignition switch 20, across distribution block 75 and 29-pole white connector 152A.
When the ignition switch is set to the parked, drive or start position, terminals 30 and X of the ignition switch will be interconnected. The +X supply will then be connected to fuses 20 and 23.
On certain markets, the +X supply is also used for the burglar alarm (connector 289) (1989 model).
Fault-tracing hints
1. Check the battery voltage.
2. Check the terminals of distribution block 75.
3. Check the terminals in 29-pole connector 152.
4. Check that the supply to each component is live.
5. Check the relevant wiring.