Power Supply (+54 Circuit)
From battery 1, positive voltage is fed via distribution block 75 to:^ Terminal block 230 (+30) and on to connection 30 on ignition switch relay 21.
^ Connection 30 on ignition switch 20.
When the ignition switch is turned to the Drive position, terminals 30 and 54 on the ignition switch are connected to each other. Current is then supplied to;
^ Fuse 3 in main fuse box 302A (ABS)
^ Fuse 31 in main fuse box 22A
^ Ignition switch relay 21
The relay contact in ignition switch 21 closes and current is supplied via terminal block 231 (+54) to:
^ Fuses 2, 3 and 5-12 in main fuse box 22A behind the glove box.
^ Fuses 3 and 9 in main fuse box 342A in the engine bay.