Operation CHARM: Car repair manuals for everyone.

B1313






Coolant temperature sensor, shorted to battery positive voltage

Fault symptom
The temperature gauge needle is at the bottom position.

The radiator fan runs continuously.

Action
1 Unplug the engine temperature sensor connector. Switch on the ignition and measure the voltage between pin 1 on the connector and ground.

The voltage should be about 1 V.

If the voltage is higher, unplug the connector from the control module and repeat the measurement.

If there is voltage, investigate the lead for short circuit to battery positive voltage.
2 If the fault remains, proceed to "Action Before Changing A Control Module".