Recirculation Flap
Recirculation Flap
Removing
1. Remove the glove box.
Remove the trim from the side of the centre console.
2. Remove the recirculation flap screws. Pull the motor straight down.
3. Unplug the connector.
4. Cut the cable tie holding the wiring harness.
5. Remove the connector from the plate.
Fitting
1. Lubricate the linkage arm with 32 025 041 Silicone grease . Lift up the recirculation flap using a screwdriver. Put the recirculation motor in place and fit its bolts.
2. Put back the connector in the plate.
3. Fasten the wiring harness with a cable tie.
4. Connect the contact.
5. Replace the side trim on the centre console.
Fit the glove box.