Operation CHARM: Car repair manuals for everyone.

Removal and Installation

REMOVAL

1. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

CAUTION: Wait at least 90 seconds after disconnecting the cable from the negative (-) battery terminal to prevent airbag and seat belt pretensioner activation.




2. REMOVE INSTRUMENT CLUSTER FINISH PANEL
a. Remove the 2 clips.
b. Using a screwdriver, detach the 6 claws and remove the cluster finish panel.

HINT: Tape the screwdriver tip before use.




3. REMOVE COMBINATION METER ASSEMBLY
a. Remove the 3 screws.
b. Disconnect the connectors and remove the combination meter.

INSTALLATION




1. INSTALL COMBINATION METER ASSEMBLY
a. Connect the connectors and install the combination meter with the 3 screws.




2. INSTALL INSTRUMENT CLUSTER FINISH PANEL
a. Attach the 6 claws to install the cluster finish panel.
b. Install the 2 clips.

3. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL

4. PERFORM INITIALIZATION
a. Perform initialization.

NOTE: Certain systems need to be initialized after disconnecting and reconnecting the cable from the negative (-) battery terminal.

5. CHECK SRS WARNING LIGHT
a. Check the SRS warning light.