Variable Induction System: Service and Repair
Tumble Generator Valve AssemblyREMOVAL
1. Disconnect the battery ground cable.
2. Remove the intake manifold.
3. Disconnect the connector from the tumble generator valve sensor.
4. Disconnect the connector from the tumble generator valve actuator.
5. Remove the fuel injector.
6. Remove the tumble generator valve body from the intake manifold.
INSTALLATION
Install in the reverse order of removal.
NOTE: Always use new gaskets.