Variable Induction System: Service and Repair

Tumble Generator Valve Assembly

REMOVAL




1. Disconnect the battery ground cable.
2. Remove the intake manifold.




3. Disconnect the connector from the tumble generator valve sensor.




4. Disconnect the connector from the tumble generator valve actuator.
5. Remove the fuel injector.




6. Remove the tumble generator valve body from the intake manifold.

INSTALLATION




Install in the reverse order of removal.

NOTE: Always use new gaskets.

Tightening torque: 8.25 N.m (0.84 kgf-m, 6.1 ft-lb)