Subaru Select Monitor
SUBARU SELECT MONITOROPERATION
1. HOW TO USE SUBARU SELECT MONITOR
1. Prepare the Subaru Select Monitor kit.
2. Connect the diagnosis cable to Subaru Select Monitor.
3. Insert the cartridge to Subaru Select Monitor.
4. Connect the Subaru Select Monitor to data link connector.
1. Data link connector is located in the lower portion of instrument panel (on the driver's side).
2. Connect the diagnosis cable to data link connector.
CAUTION: Do not connect scan tools except for Subaru Select Monitor and general scan tool.
5. Turn the ignition switch to ON (engine OFF) and Subaru Select Monitor switch to ON.
6. Using the Subaru Select Monitor, call up DTCs and various data, then record them.
2. READ DIAGNOSTIC TROUBLE CODE (DTC) FOR ENGINE (NORMAL MODE)
Refer to "Read Diagnostic Trouble Code" for information about how to indicate DTC. Reading Diagnostic Trouble Codes
3. READ DIAGNOSTIC TROUBLE CODE (DTC) FOR ENGINE (OBD MODE)
Refer to "Read Diagnostic Trouble Code" for information about how to indicate DTC. Reading Diagnostic Trouble Codes
4. READ CURRENT DATA FOR ENGINE (NORMAL MODE)
1. On the "Main Menu" display screen, select the {Each System Check} and press the [YES] key.
2. On the "System Selection Menu" display screen, select the {Engine Control System} and press the [YES] key.
3. Press the [YES] key after the information of engine type has been displayed.
4. On the "Engine Diagnosis" display screen, select the {Current Data Display/Save}, and then press the [YES] key.
5. On the "Display Menu" screen, select the {Data Display} and press the [YES] key.
6. Using the scroll key, scroll the display screen up or down until the desired data is shown.
Part 1:
Part 2:
- A list of the support data is shown in the table.
5. READ CURRENT DATA FOR ENGINE (OBD MODE)
1. On the "Main Menu" display screen, select the {Each System Check} and press the [YES] key.
2. On the "System Selection Menu" display screen, select the {Engine Control System} and press the [YES] key.
3. Press the [YES] key after the information of engine type has been displayed.
4. On the "Engine Diagnosis" display screen, select the {OBD System} and press the [YES] key.
5. On the "OBD Menu" display screen, select the {Current Data Display/Save}, and then press the [YES] key.
6. On the "Display Menu" screen, select the {Data Display} and press the [YES] key.
7. Using the scroll key, scroll the display screen up or down until the desired data is shown.
- A list of the support data is shown in the table.
6. READ FREEZE FRAME DATA FOR ENGINE (OBD MODE)
1. On the "Main Menu" display screen, select the {Each System Check} and press the [YES] key.
2. On the "System Selection Menu" display screen, select the {Engine Control System} and press the [YES] key.
3. Press the [YES] key after the information of engine type has been displayed.
4. On the "Engine Diagnosis" display screen, select the {OBD System} and press the [YES] key.
5. On the "OBD Menu" display screen, select the {Freeze Frame Data} and press the [YES] key.
- A list of the support data is shown in the table.
7. LED OPERATION MODE FOR ENGINE
1. On the "Main Menu" display screen, select the {Each System Check} and press the [YES] key.
2. On the "System Selection Menu" display screen, select the {Engine Control System} and press the [YES] key.
3. Press the [YES] key after the information of engine type has been displayed.
4. On the "Engine Diagnosis" display screen, select the {Current Data Display/Save}, and then press the [YES] key.
5. On the "Data Display" screen, select the {Data LED Display} and press the [YES] key.
6. Using the scroll key, scroll the display screen up or down until the desired data is shown.
Part 1:
Part 2:
- A list of the support data is shown in the table.
8. V.I.N. REGISTRATION
1. On the "Main Menu" display screen, select the {Each System Check} and press the [YES] key.
2. On the "System Selection Menu" display screen, select the {Engine Control System} and press the [YES] key.
3. Press the [YES] key after the information of engine type has been displayed.
4. On the "Engine Diagnosis" display screen, select the {V.I.N. Registration} and press the [YES] key.
5. Perform the procedures shown on the display screen.
NOTE: For detailed operation procedure, refer to the "SUBARU SELECT MONITOR OPERATION MANUAL".