Variable Valve Timing Pressure Switch: Service and Repair
Variable Valve Lift Diagnosis Oil Pressure SwitchREMOVAL
1. Disconnect the ground cable from battery.
2. Remove the air intake chamber.
3. Remove the engine harness connector from the racket.
4. Disconnect the connector from the variable valve lift diagnosis oil pressure switch.
5. Remove the variable valve lift diagnosis oil pressure witch.
- LH side
- RH side
INSTALLATION
Install in the reverse order of removal.
NOTE: Apply liquid gasket to the variable valve lift diagnosis oil pressure switch threads.
Liquid gasket: Three bond 1324 (Part No.004403042) or equivalent