Backup Lamp Switch: Service and Repair
Back Up Lamp Switch Removal and InstallationRemoval
1) Remove battery and tray with ECM.
2) Remove air cleaner assembly.
3) Disconnect back up lamp switch connector (1).
4) Remove back up lamp switch.
Installation
Reference: Back Up Lamp Switch Inspection
1) Apply oil to new O-ring (1) and tighten back up lamp switch (2) to specified torque.
Tightening torque
Back up lamp switch (a): 19 Nm (1.9 kg-m, 14.0 lbf-ft)
2) Connect back up lamp switch connector.
3) Install air cleaner assembly.
4) Install battery and tray with ECM.