A/C Refrigerant Pressure Sensor Removal and Installation
A/C Refrigerant Pressure Sensor Removal and Installation
Removal
1) Recover refrigerant from the A/C system with the recovery and recycling equipment referring to "Recovery" in Service and Repair Operation Procedure for Refrigerant Charge:Manual A/C.
2) Disconnect negative (-) cable from battery.
3) Disconnect A/C refrigerant pressure sensor connector.
4) Remove A/C refrigerant pressure sensor (1) from liquid pipe (2).
Installation
Reverse removal procedure noting the following instructions.
- Apply compressor oil to O-ring of A/C refrigerant pressure sensor.
- Tighten A/C refrigerant pressure sensor to specified torque.
Tightening torque
A/C refrigerant pressure sensor (a): 11 Nm (1.1 kgf-m, 8.0 lbf-ft)
- Evacuate and charge the A/C system referring to "Evacuation" and "Charge" in Service and Repair Operation Procedure for Refrigerant Charge:Manual A/C.