Service Hints
D 7 DOOR LOCK CONTROL RELAY8-Ground: Always Approx. 12 Volts
16-Ground: Always continuous
1-Ground: Approx. 12 Volts with the Ignition SW at ON position
2-Ground: Continuous with the LH Door open
14-Ground: continuous with the RH Door open
15-Ground: Approx. 12 Volts with the Ignition SW ON and stays at 12 Volts for 60 Seconds after the Ignition SW is turned OFF, but if the door is opened in this 60 Seconds period, voltage will drop to 0 Volts
D10, D11 DOOR COURTESY SW LH, RH
1-Ground: Closed with the Door open
P 6 POWER WINDOW CONTROL SW (PASSENGER'S SIDE)
4-Ground: Approx. 12 Volts with the Ignition SW ON and stays at 12 Volts for 60 Seconds after the Ignition SW is turned OFF, but if the Door is opened in this 60 Seconds period, Voltage will drop to 0 Volts
P 7 POWER WINDOW MASTER SW
9-Ground: Always Continuous
7-Ground: Approx. 12 Volts with the Ignition SW ON and stays at 12 Volts for 60 Seconds after the Ignition SW is turned OFF, but if the Door is opened in this 60 Seconds period. voltage will drop to 0 Volts
8-Ground: Approx. 12 Volts with the Ignition SW at ON position and the master SW at up position
6-Ground: Approx. 12 Volts with the Ignition SW at ON position and the master SW at Down or Auto Down position
Q 1, Q 2 QUARTER POWER WINDOW SW LH. RH
4-Ground: Approx. 12 Volts with Ignition SW ON and stays at 12 Volts for 60 Seconds after the Ignition SW is turned OFF, but if a Door is opened in this 60 Seconds period, voltage will drop to 0 volts
WINDOW LOCK SW
Open with the Window lock SW at Normal position