Combination Meter (Canada)
B 2 BRAKE FLUID LEVEL WARNING SW1-2: Closed with the flow Down
P 2 PARKING BRAKE SW
1-GROUND: Closed with the Parking Brake Lever Pulled UP
O 1 OIL PRESSURE SW
1-Ground: Opened with the oil pressure above 0.2 kg/cm2 (2.8 psi, 19.6 kPa)
W2 WATER TEMP. SENDER
1-Ground: Approx. 160-240 Ohms (50° C, 122° F)
Approx. 17.1-20.4 Ohms (120° C, 248° F)
F10 FUEL SENDER
1-2: Approx. 3 Ohms at Fuel full
Approx. 110 Ohms at Fuel empty
C 8-A, C9-B, C10-C COMBINATION METER
A-8, B-4-Ground: Approx. 12 Volts the Ignition SW at ON position
B-6, B-9, B-16, C-4-Ground: Always Continuous
A-3, B-10-Ground: Always Approx. 12 Volts