Service Hints
P 6 POWER WINDOW MASTER SW9-GROUND: Approx. 12 Volts with Ignition SW at ON position
6-GROUND: Always continuity
4-GROUND: Approx. 12 Volts with Ignition SW ON and the Power Window Master SW (Driver's Window) at DOWN or AUTO DOWN position
3-GROUND: Approx. 12 Volts with Ignition SW ON and the Power Window Master SW (Driver's Window) at UP position
WINDOW LOCK SW
Open with the Window Lock SW at LOCK position