Service Hints
P16 POWER WINDOW MASTER SW10, 11-GROUND : Approx. 12 Volts with ignition SW at ON position
4, 3-GROUND : Always continuity
1-GROUND : Approx. 12 Volts with ignition SW ON and master SW at UP position
5-GROUND : Approx. 12 Volts with ignition SW ON and master SW at DOWN or AUTO DOWN position
WINDOW LOCK SW
Open with window lock SW at LOCK position