Heated Oxygen Sensor (Bank 1,2 Sensor 1)
INSPECT HEATER RESISTANCE OF HEATED OXYGEN SENSORS(Bank 1 Sensor 1, Bank 2 Sensor 1)
a. Disconnect the oxygen sensor connector.
b. Using an ohmmeter, measure the resistance between the terminals +B and HT.
Resistance: 11 - 16 Ohms at 20°C (68°F)
If the resistance is not as specified, replace the sensor.
Torque: 44 N.m (440 kgf.cm, 31 ft.lbf)
c. Reconnect the oxygen sensor connector.